Virtual source failed becoming physical.

This error can occur when a voice that has previously played was put into Virtual mode, then was requested to become physical (audible) again. With hardware codecs such as ATRAC9 and Opus, the hardware limitations may have been reached while the voice was virtual.

Probable causes:

  • A hardware codec was prevented from reinitializing because of hardware constraints.

  • There was not enough memory to allocate working data. If this is the case, the error would be preceded by an Insufficient Memory error in the Capture Log.

Recommended resolution steps: