The following settings can be defined for the Loudness Meter:
Interface Element |
Description |
---|---|
Target Level |
Defines the target level value, appearing in green. This value also defines the LUFS to LU conversion function. EBU recommended value: -23 LUFS |
Target Range |
Defines the range target region (in green). For example, a 1 LU target range with a target level of -23 LUFS defines the green region from -24 to -22. EBU recommended value: 1 LU Sony Worldwide Studios Audio Standards Working Group (ASWG) recommended value: 2 LU |
Target Extended Range |
Defines the range of the extended region (in yellow) |
Scale |
Standard: -18 LU to +9 LU (-41 LUFS to -14 LUFS) Extended:-36 LU to +18 LU (-59 LUFS to -5 LUFS) |
Unit |
LU (Loudness Units): target level is at 0 LU LUFS (Loudness Units Full Scale): target level is specified by target level (default of -23 LUFS). |