The Monitor Queue, used by the Wwise Profiler, is full and could not contain one message. The only side effect of this error is a missing message in the Wwise Profiler.
Probable causes:
When using API profiling, this can occur if there is a burst of API calls in a very short period.
The monitoring thread could not be run in time due to thread priorities on the same CPU core.
Recommended resolution steps:
Increase AkInitSettings::uMonitorQueuePoolSize
.
Call AK::SoundEngine::RenderAudio
more regularly to avoid bursts of API calls.
Using a CPU profiler, validate the thread priorities of all threads sharing the same CPU core.
Des questions ? Des problèmes ? Besoin de plus d'informations ? Contactez-nous, nous pouvons vous aider !
Visitez notre page d'AideEnregistrez votre projet et nous vous aiderons à démarrer sans aucune obligation !
Partir du bon pied avec Wwise