The Wwise Meter plug-in Effect measures the level of a signal without modifying it, and optionally outputs this level as a Game Parameter. The dynamics as well as the range of the output value can be adjusted. It is most useful for achieving side-chaining, where the measured level of a bus drives the volume of another bus through RTPC.

Wwise Meter Properties

Interface Element

Description

Inclusion

Determines whether the element is included or excluded. When selected, the element is included. When unselected, the element is not included. By default, this applies across all platforms. Use the Link indicator (to the left of the check box) to determine or to set platform-specific customizations.

When this option is unselected, the property and behavior options in the Property Editor become unavailable.

Name

The name of the Effect instance.

Effect instances are a group of effect property settings. They can be one of two types: custom instances or ShareSets. Custom instances can be used by only one object, whereas ShareSets can be shared across several objects.

Effect

The type of effect.

Shared by (Used by)

A list of objects that currently subscribe to the selected ShareSet.

This field is called “Used by” when editing a custom instance of the Effect.

Opens a search field where standard alphanumeric entries filter out unmatching elements from the view. Learn more in Using Tables.

Click the Close icon to the left of the search icon to close the search field and remove the filter.

[Note] Note

The searches do not include elements in collapsed nodes of the List View, Query Editor, MIDI Keymap Editor, and Reference View.

Returns the Effect property settings to their default values.

This option is only available when editing a custom instance of the Effect.

Notes

Additional information about the Effect.

Effect Settings

Mode

The metering mode. This plug-in can be set to track either peak values or RMS.

  • Peak: Sets the meter to be in Peak mode, which tends to be more reactive to transients.

  • RMS: Sets the meter to be in RMS mode, which might be better suited for voice work.

Scope

  • Global: Sets the meter to work on all input into the applicable Wwise audio element (be it a bus, container, Music Segment, or anything else), treating multiple game object instances of the element as a collective single game object.

  • Game Object: Sets the meter to apply to input into each game object instance.

Dynamics

Attack

The time it takes for the output value to rise by 10 decibels, when the monitored level is above the current output value.

Default value: 0
Range: 0 to 10
Units: Seconds

Hold

The time it takes for the output value to start falling, from the moment where the monitored level goes below the current output value.

Default value: 0
Range: 0 to 10
Units: Seconds

Release

The time it takes for the output value to fall by 10 decibels, when the monitored level is below the current output value.

Default value: 0
Range: 0 to 10
Units: Seconds

Output Game Parameter

When set, the output value will be sent to this Game Parameter based on the playing instance's Scope, be it a specific Game Object or globally.

[Tip] Tip

Make sure that the range of the selected Game Parameter contains the output value range. For more information on setting the Game Parameter range, refer to Property Editor: Game Parameter.

Min

The minimum output value.

Default value: -48
Range: -96.3 to 0
Units: dB

Max

The maximum output value.

Default value: 0
Range: -96.3 to 12
Units: dB

Apply downstream volume

When enabled, the meter will display volume gains applied at a higher level. For example, if the volume of the Master Audio Bus is increased by 10 and that of a child Audio Bus is decreased by 15, then all its children will inherit the sum total gain of -5. Although the gain is always audible, unless this option is enabled the meter will normally not show it.

(VU Meters)

A pair of meters that display the input level of the audio signal, and output value of the Game Parameter.

To enable the VU meters, you must click the Start Capture button in the Wwise toolbar.

The VU meters only work when the Effect has been applied to a bus in the Master-Mixer Hierarchy. In the case of a ShareSet, the bus must be selected in the 'Shared by' list of the Effect Editor.


Cette page a-t-elle été utile ?

Besoin d'aide ?

Des questions ? Des problèmes ? Besoin de plus d'informations ? Contactez-nous, nous pouvons vous aider !

Visitez notre page d'Aide

Décrivez-nous de votre projet. Nous sommes là pour vous aider.

Enregistrez votre projet et nous vous aiderons à démarrer sans aucune obligation !

Partir du bon pied avec Wwise