Version

menu_open

Contents Editor: Actor-Mixer

This Contents Editor gives you quick access to some of the most common properties associated with objects within the actor-mixer.

Interface Element

Description

Name

The name of the object.

Inclusion

Determines whether the element is included or excluded. When selected, the element is included. When unselected, the element is not included. By default, this applies across all platforms. Use the Link indicator (to the left of the check box) to determine or to set platform-specific customizations.

When this option is unselected, the property and behavior options in the Property Editor become unavailable.

Voice Volume

The attenuation (level or amplitude) applied on the current object before it is routed to a bus or sent to an Auxiliary Bus. Refer to Understanding the Voice Pipeline for more information about volumes.

Default value: 0
Range: -400 to 400
Units: dB

[Note] Note

The default slider range is from -96 to +12 dB. You can go over those limits by entering the value directly or by rolling the mouse while the focus is on the edit control.

Voice Pitch

The playback speed of an audio object, where:

  • Pitch 0 = Normal speed.

  • Pitch 1,200 = 2 x speed.

  • Pitch 2,400 = 4 x speed.

  • Pitch 4,800 = 8 x speed.

  • Pitch -1,200 = 0.5 speed

  • Pitch -2,400 = 0.25 speed

  • Pitch -4,800 = 0.125 speed

[Tip] Tip

1,200 cents is equivalent to one octave.

Default value: 0
Range: -4,800 to +4,800
Units: Cents

Voice Low-pass Filter

A recursive filter that attenuates high frequencies based on the value specified.

The units for this filter represent the percentage of low-pass filtering that has been applied, where 0 means no low-pass filtering (signal unaffected) and 100 means maximal attenuation.

Default value: 0
Range: 0 to 100
Units: Percent
(For more detail, see Wwise LPF and HPF Value Cutoff Frequencies.)

Voice High-pass Filter

A recursive filter that attenuates low frequencies based on the value specified.

The units for this filter represent the percentage of high-pass filtering that has been applied, where 0 means no high-pass filtering (signal unaffected) and 100 means maximal attenuation.

Default value: 0
Range: 0 to 100
Units: Percent

Notes

Any additional information about the object properties.


Cette page a-t-elle été utile ?

Besoin d'aide ?

Des questions ? Des problèmes ? Besoin de plus d'informations ? Contactez-nous, nous pouvons vous aider !

Visitez notre page d'Aide

Décrivez-nous de votre projet. Nous sommes là pour vous aider.

Enregistrez votre projet et nous vous aiderons à démarrer sans aucune obligation !

Partir du bon pied avec Wwise